­º­¶ > ²£«~®i¥Ü> TE Connectivity ®õ¬ìÄ~¹q¾¹(tyco) > °ªÀ£¤Î¤j¹q¬yÄ~¹q¾¹High Voltage & Circuit Relays
 
·Ó¤ù
¯S©Ê

 
²£«~½s¸¹: HC-2
³W®æ¯S©Ê: • 8.0kV, No Load Switching, SPDT
• Vacuum dielectric and copper contacts for
high current carry rating of 25 Amps
• Not designed for power switching
• Stable, low contact resistance
• Meets requirements of MIL-R-83725

 
²£«~½s¸¹: HC-3
³W®æ¯S©Ê: • 3.5kV, Make & Break Load Switching, SPDT
• Tungsten contacts for long life when power
switching
• Vacuum dielectric for power switching low
current loads

 
²£«~½s¸¹: HC-4
³W®æ¯S©Ê: • 8.0kV, Make & Break Load Switching, SPDT
• Tungsten contacts for long life in power
switching applications
• Vacuum dielectric for arc suppression when
making or breaking a load
• Widely used in defibillator applications
• Meets requirements of MIL-R-83725

 
²£«~½s¸¹: HC-5
³W®æ¯S©Ê: • 3.5kV, Make Only Switching, SPDT
• Gas-filled for ¡§make only¡¨ power switching
• SF-6 gas filled for capacitive discharge
applications

 
²£«~½s¸¹: HC-6
³W®æ¯S©Ê: • 8.0kV, Make Only Switching, SPDT
• Tungsten contacts for switching high in-rush
loads
• SF-6 gas-filled for capacitive discharge
applications
• Ideal for ESD testing applications

 
²£«~½s¸¹: K40P
³W®æ¯S©Ê: • 5.0kV, Make & Break Load Switching, SPST-Latching
• Vacuum dielectric for power switching low
current loads
• Fast, 1 millisecond operate time
• Long life: 10 million cycles
• 35 Amps continuous current rating at dc;
8 Amps at 32 mHz
• Ideal for high power antenna couplers
• Meets requirements of MIL-R-83725

 
²£«~½s¸¹: K41A
³W®æ¯S©Ê: • 5.0kV, Make & Break Load Switching, SPST-NO
• High current carry rating
• Vacuum dielectric for power switching low
current loads
• Glazed ceramics for low current leakage
• Compact, space-saving design
• Meets requirements of MIL-R-83725
• QPL versions available, M83725/21 &
M83725/22

 
²£«~½s¸¹: K41B
³W®æ¯S©Ê: • 5.0kV, Make & Break Load Switching, SPST-NC
• High current carry rating
• Vacuum dielectric for power switching low
current loads
• Glazed ceramics for low current leakage
• Compact, space-saving design
• Meets requirements of MIL-R-83725
• QPL versions available, M83725/21 &
M83725/22

 
²£«~½s¸¹: K41C
³W®æ¯S©Ê: • 5.0kV, Make & Break Load Switching, SPDT
• Single pole, double throw version
• Vacuum dielectric for power switching low
current loads
• RF ratings to 32 MHz
• Long life: 2 million cycles
• Meets requirements of MIL-R-83725
• QPL version available, M83725/23
 

·s¥_¥« ²H¤ô°Ï ¤¤¥¿ªF¸ô¤G¬q 27-8¸¹ 12¼Ó
¹q¸Ü:(02)2808-0678 ¶Ç¯u:(02)2808-0066