­º­¶ > ²£«~®i¥Ü> TE Connectivity ®õ¬ìÄ~¹q¾¹(tyco) > ¤p«¬¥\²vÄ~¹q¾¹Min Power Relays 3A-30A
 
·Ó¤ù
¯S©Ê

 
²£«~½s¸¹: PCD/PCDF
³W®æ¯S©Ê: Dimensions(L x W x H)(mm):23.0 x 16.1 x 10.2
1 Form A (SPST-NO).
15A @ 125VAC resistive
10A @ 250VAC resistive,
10A @ 24VDC resistive.
5A @ 125VAC inductive (cosø= 0.4, L/R=7msec),
5A @ 24VDC inductive (cosø= 0.4, L/R=7msec).
Max. Switched Current: 15A
Max. Switched Voltage: AC: 250V/DC: 24V.

 
²£«~½s¸¹: RT(DC Coil)
³W®æ¯S©Ê: Dimensions(L x W x H)(mm):29 x 12.7 x 15.7
1 Form A.2 Form A.1 Form C.2 Form C
16A @ 250VAC/30VDC
12A @ 250VAC/30VDC
8A @ 250VAC/30VDC
Max. Switched Current:16A
Max. Switched Voltage: AC 400V/ DC 30V.
Ambient temperature range¡G-40 ~ +85¢XC
Low profile case
10mm coil- tocontact spacing for 5kV isolation

 
²£«~½s¸¹: RT(AC Coil)
³W®æ¯S©Ê: Dimensions(L x W x H)(mm):29 x 12.7 x 15.7
1 Form A.2 Form A.1 Form C.2 Form C
16A @ 250VAC/30VDC
12A @ 250VAC/30VDC
8A @ 250VAC/30VDC
Max. Switched Current:16A
Max. Switched Voltage: AC 400V/ DC 30V.
Ambient temperature range¡G-40 ~ +70¢XC
Immersion cleanable or fluxtight case
Low profile case
10mm coil- tocontact spacing for 5kV isolation

 
²£«~½s¸¹: RT Sensitive
³W®æ¯S©Ê: Dimensions(L x W x H)(mm):29 x 12.7 x 15.7
1 Form A.2 Form A.1 Form C.2 Form C
16A @ 250VAC/30VDC
12A @ 250VAC/30VDC
8A @ 250VAC/30VDC
Max. Switched Current:16A
Max. Switched Voltage: AC 400V/ DC 30V.
Ambient temperature range¡G-40 ~ +70¢XC
Immersion cleanable or fluxtight case
Low profile case
10mm coil- tocontact spacing for 5kV isolation

 
²£«~½s¸¹: RTH 105¢XC 16A
³W®æ¯S©Ê: Dimensions(L x W x H)(mm):29 x 12.7 x 15.7
1 Form A and 1 Form C.1 Form C notavailable with sensitive coil.
16A @ 250VAC
Rated current: 16 A
Rated voltage: AC 240/400 VAC
Ambient temperature range¡G-40 ~ +105¢XC
Low profile case
10mm coil-tocontact spacing for 5kV isolation

 
²£«~½s¸¹: RT1 Inrush
³W®æ¯S©Ê: Dimensions(L x W x H)(mm):29 x 12.7 x 15.7
1 Form A
16A @ 250VAC
80A for 20ms
Ambient temperature range¡G-40 ~ +85¢XC
Handles inrush currents to 80A
Low profile case
10mm coil- tocontact spacing for 5kV isolation

 
²£«~½s¸¹: RT1 Inrush Power
³W®æ¯S©Ê: Dimensions(L x W x H)(mm):29 x 12.7 x 15.7
1 Form A
16A @ 250VAC
165A for 20ms
Ambient temperature range¡G-40 ~ +85¢XC
Handles inrush currents to 80A
Low profile case
10mm coil- tocontact spacing for 5kV isolation

 
²£«~½s¸¹: RF
³W®æ¯S©Ê: Dimensions(L x W x H)(mm):29 x 12.7 x 15.7
1 Form A or 1 Form B,
Rated current:16 A
Rated voltage: AC 240 VAC

 
²£«~½s¸¹: RP II/1
³W®æ¯S©Ê: Dimensions(L x W x H)(mm):29.0 x 12.6 x 25.5
1 Form A and 1 Form C, single contact.
Rated current: 8A/12A/16A
Rated voltage: AC 250 Vac / 440 Vac